{"product_id":"philips-pagewriter-tc35-12-channel-ecg-machine","title":"Philips PageWriter TC35 12 Channel ECG Machine","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ePhilips PageWriter TC35 12 Channel ECG Machine\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is an advanced professional cardiograph designed for hospitals, clinics, emergency departments, cardiology units and other healthcare environments requiring reliable 12-lead ECG acquisition. It captures all \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e12 ECG leads simultaneously\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and combines ECG recording with advanced interpretation, reporting and connectivity capabilities.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe TC35 incorporates the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ePhilips DXL ECG Algorithm\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, which provides more than 600 interpretive statements and includes integrated pediatric analysis. Philips also specifies support for pacemaker pulse detection, QT measurements and STEMI-related decision-support tools. These features are intended to support clinical workflow; ECG results should always be reviewed by appropriately qualified healthcare professionals.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eDesigned for demanding clinical environments, the PageWriter TC35 combines a touchscreen interface, light-guided buttons, integrated leadset, thermal printing and network connectivity. It supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eLAN and Wi-Fi connectivity\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, DICOM ECG output, modality worklists and supported HL7\/ADT workflows, making it particularly relevant for hospitals that want ECG equipment integrated with existing digital healthcare systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003eWhy Choose This Product?\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Philips PageWriter TC35 is a strong choice for hospitals and healthcare facilities that require more than basic ECG recording.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eKey reasons to consider it:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e12-lead simultaneous ECG acquisition\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePhilips DXL ECG Algorithm\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMore than 600 interpretive statements\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIntegrated pediatric analysis\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePacemaker pulse detection\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eQT measurement support\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSTEMI decision-support tools\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e6.5-inch TFT display\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTouchscreen operation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLight-guided buttons\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e1-2-3 workflow\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIntegrated leadset\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBuilt-in thermal printer\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLAN connectivity\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWi-Fi 5 connectivity\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDICOM ECG output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eModality worklist support\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHL7\/ADT integration support\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInternal storage for up to 200 ECGs\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFull-fidelity 1000 Hz acquisition\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBattery operation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUp to approximately 13.9 hours of normal operating cycles\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCompact hospital-oriented design\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan\u003e12-Lead Simultaneous ECG Acquisition\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe PageWriter TC35 acquires \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eall 12 ECG leads simultaneously\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, supporting standard diagnostic 12-lead ECG workflows.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003ePhilips DXL ECG Algorithm\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe TC35 uses the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ePhilips DXL ECG Algorithm\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, developed from decades of Philips ECG research. Philips specifies more than \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e600 interpretive statements\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and integrated pediatric analysis.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eAdvanced Pediatric Analysis\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIntegrated pediatric analysis makes the TC35 suitable for healthcare environments where ECG examinations may involve pediatric patients.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003ePacemaker Pulse Detection\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePhilips specifies pacemaker pulse detection capability for pulses as small as \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e0.02 mVms\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, supporting ECG acquisition for patients with pacemakers.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eQT Measurement\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe DXL algorithm provides advanced ECG interpretation capabilities including QT-related measurements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eSTEMI Decision-Support Tools\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe system includes advanced STEMI-related decision-support features, including graphical ST vector information and critical-value highlighting. These features support—not replace—professional clinical assessment.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eTouchscreen Workflow\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe TC35 uses a touchscreen interface together with light-guided buttons and a simplified \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1-2-3 workflow\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for ECG acquisition and reporting.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eIntegrated Leadset\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe integrated leadset design reduces the number of separate equipment connections that staff need to manage during routine ECG procedures.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eFull-Fidelity ECG Acquisition\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe TC35 supports full-fidelity recording at \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1000 Hz for 10 seconds across all 12 leads\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eDICOM Connectivity\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe machine supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eDICOM 12-lead ECG output\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and DICOM General ECG functionality, helping facilities integrate ECG results into compatible digital healthcare environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eLAN \u0026amp; Wi-Fi Connectivity\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eConnectivity includes \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e10\/100 Base-TX Ethernet\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e802.11 b\/a\/g\/n\/ac Wi-Fi 5\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with WPA3 Personal and WPA2 Enterprise security options listed by Philips.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eInternal ECG Storage\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe PageWriter TC35 can store up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e200 ECGs internally\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e according to Philips' specifications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eBarcode Data Entry\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAn optional barcode reader can be used for supported patient-data entry workflows, helping reduce manual demographic-data entry.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003eBenefits\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan\u003eEfficient 12-Lead ECG Workflow\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eSimultaneous acquisition of all 12 leads allows the machine to capture a complete standard ECG efficiently.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eAdvanced Clinical Decision Support\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Philips DXL algorithm provides extensive interpretation capabilities, including pediatric analysis, QT measurements, pacemaker pulse detection and STEMI-related tools.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eHospital Connectivity\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eDICOM, LAN, Wi-Fi and supported HL7\/ADT connectivity can help integrate ECG workflows with compatible hospital information systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eReduced Manual Data Entry\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eSupported patient-data retrieval and optional barcode scanning can reduce repetitive demographic-data entry.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eEasy Clinical Operation\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe touchscreen interface and light-guided controls are designed around a simplified workflow for ECG acquisition.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eSuitable for Mobile Hospital Use\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBattery operation allows the unit to be used for ECG acquisition away from a fixed workstation, subject to battery condition and operating requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eReliable ECG Reporting\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe integrated thermal printer allows ECG reports to be produced directly from the cardiograph.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eSupports Pediatric ECG Workflows\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe integrated pediatric analysis makes the TC35 suitable for facilities serving both adult and pediatric patients.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h1\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePhilips Healthcare\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Name\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePhilips PageWriter TC35 ECG Machine\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePageWriter TC35\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 Channel Hospital ECG Machine\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eECG Channel Print\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 Channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLead Acquisition\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 Simultaneous Leads\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eECG Algorithm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePhilips DXL ECG Algorithm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInterpretive Statements\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMore than 600\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePediatric Analysis\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePacemaker Pulse Detection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDown to 0.02 mVms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDisplay\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTFT Active-Matrix\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDisplay Size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6.5 Inch\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDisplay Resolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e640 × 480 VGA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDisplay Colours\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e64K\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTouchscreen\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTouchscreen + Light-Guided Buttons\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eECG Sampling\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFull Fidelity at 1000 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRecording Duration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 seconds for all 12 leads\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInternal Storage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 200 ECGs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExternal Storage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 200 ECGs with optional USB device\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eThermal Printer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLAN\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10\/100 Base-TX Ethernet\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWireless\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e802.11 b\/a\/g\/n\/ac Wi-Fi 5\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWireless Security\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWPA3 Personal \/ WPA2 Enterprise\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDICOM\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDICOM 12-lead ECG \/ General ECG\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHL7\/ADT\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupported through compatible Philips hospital systems\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModality Worklist\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupported\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBarcode Reader\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOptional\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBattery Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLithium-Ion\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBattery Operation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to approximately 13.9 hours of normal operation cycles\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eContinuous Operation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApproximately 10 hours without printing, as listed\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRecharge Time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApproximately 4 hours\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e31 × 40 × 21 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApproximately 8.6 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAC Input\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100–240 VAC, 50–60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10°C to 40°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Humidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10–90% RH, non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Altitude\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 3,048 m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20°C to 50°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage Humidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10–90% RH, non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage Altitude\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 4,572 m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 Year – Manufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCountry of Manufacture\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAs per manufacturer specifications\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1\u003e\u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan\u003e1. What is the Philips PageWriter TC35?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Philips PageWriter TC35 is a professional \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e12-channel ECG machine\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e designed for hospitals, clinics and healthcare facilities requiring simultaneous 12-lead ECG acquisition and advanced ECG interpretation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e2. Does the Philips PageWriter TC35 record all 12 ECG leads simultaneously?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYes. The TC35 provides simultaneous acquisition of \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e12 ECG leads\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e3. What ECG algorithm does the PageWriter TC35 use?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe TC35 uses the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ePhilips DXL ECG Algorithm\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with more than 600 interpretive statements and integrated pediatric analysis.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e4. Does the PageWriter TC35 support pediatric ECG analysis?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYes. Philips specifies integrated pediatric analysis within the DXL ECG Algorithm.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e5. Does the Philips TC35 support pacemaker pulse detection?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYes. Philips specifies pacemaker pulse detection for pulses as small as \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e0.02 mVms\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e6. Does the PageWriter TC35 have a touchscreen?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYes. The TC35 uses a touchscreen interface along with light-guided buttons.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e7. Can the Philips TC35 connect to a hospital PACS or EMR?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYes. The TC35 supports DICOM ECG output, modality worklists and supported HL7\/ADT workflows. Connectivity includes wired LAN and Wi-Fi. Actual integration depends on the hospital's compatible systems and configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e8. How many ECGs can the PageWriter TC35 store?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePhilips specifies internal storage for up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e200 ECGs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. External storage of up to 200 ECGs is also specified when using an optional USB device.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e9. What is the weight of the Philips PageWriter TC35?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe machine weighs approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e8.6 kg\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, including the battery, lead wires, clips, electrode pack and paper pack according to Philips.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e10. What is the battery backup of the PageWriter TC35?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003ePhilips specifies up to approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e13.9 hours of normal operating cycles\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e before recharge. Approximately 10 hours of continuous use without printing is also listed by the retail specification. Actual battery performance depends on usage conditions.\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/medin.co.in%20%E2%80%BA%20collections%20%E2%80%BA%20ecg-machines\"\u003e\u003cstrong\u003eEXPLORE MORE EGC MACHINES ON MEDIN\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"MEDIN","offers":[{"title":"Default Title","offer_id":48207511814309,"sku":null,"price":169118.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/8786\/4997\/files\/Philips_PageWriter_TC35_12_Channel_ECG_Machine_with_touchscreen_display.webp?v=1788265737","url":"https:\/\/medin.co.in\/products\/philips-pagewriter-tc35-12-channel-ecg-machine","provider":"MEDIN","version":"1.0","type":"link"}