{"product_id":"philips-pagewriter-tc20-12-channel-ecg-machine","title":"Philips PageWriter TC20 12-Channel ECG Machine with Touchscreen \u0026 DXL Algorithm","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ePhilips PageWriter TC20 12-Channel ECG Machine\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is a professional electrocardiograph designed for routine and advanced 12-lead ECG acquisition in hospitals, clinics, diagnostic centres and cardiac care environments. It combines a touchscreen interface, simultaneous 12-lead acquisition, built-in thermal printing and Philips ECG analysis technology to support an efficient ECG workflow.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe TC20 supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003esimultaneous acquisition of all 12 leads\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and provides multiple ECG report formats, including 3×4, 3×4 with rhythm leads, 6×2 and 12×1 configurations. Philips documentation also specifies support for standard and Cabrera formats, rhythm strips, timed ECGs and full-fidelity ECG data storage\/transfer.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA key feature is the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ePhilips DXL ECG Algorithm\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, which provides automated ECG interpretation and a broad range of measurements. Depending on the configured software options, the system can also support advanced features such as STEMI diagnostic aids, ECG data formats and hospital-network workflows. These automated outputs are intended to support—not replace—professional clinical interpretation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003eWhy Choose This Product?\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch3\u003e\u003cspan\u003e12-Lead Simultaneous ECG Acquisition\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe TC20 acquires all 12 ECG leads simultaneously, supporting standard diagnostic ECG workflows.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003ePhilips DXL ECG Algorithm\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe integrated DXL algorithm provides automated interpretive statements and ECG measurements to assist qualified healthcare professionals.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eTouchscreen Interface\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe touchscreen provides a streamlined interface for patient entry, ECG acquisition, waveform review and report workflow.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eBuilt-In Thermal Printer\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe integrated printer enables immediate production of ECG reports using compatible thermal\/A4-format recording media.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eMultiple Report Formats\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe TC20 supports multiple report configurations including 3×4, 6×2 and 12×1 formats, with additional rhythm-lead configurations.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eLead-Off Advisory\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe system provides signal-quality information and lead-off advisory features to help identify disconnected or poorly connected electrodes.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eHospital Connectivity\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eDepending on configuration and installed options, the TC20 can support USB and network-based data workflows, including PDF, XML and DICOM ECG formats.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003ePhilips PageWriter TC20\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e12-channel ECG machine\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSimultaneous 12-lead acquisition\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eColor touchscreen display\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePhilips DXL ECG Algorithm\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAutomatic ECG interpretation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eStandard ECG measurements\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAuto, manual and rhythm modes\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBuilt-in thermal printer\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMultiple ECG print formats\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eStandard and Cabrera ECG formats\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUp to 12 configurable rhythm leads\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLead-off advisory\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLead-placement assistance\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eContinuous heart-rate display\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eECG print preview\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUSB connectivity\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLAN\/network connectivity\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOptional wireless connectivity depending on configuration\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePDF\/XML\/DICOM data support depending on configuration\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRechargeable lithium-ion battery\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProfessional hospital ECG design\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003eBenefits\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch3\u003e\u003cspan\u003eEfficient 12-Lead ECG Workflow\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eSimultaneous acquisition of 12 leads allows healthcare professionals to obtain a complete standard ECG recording within a streamlined workflow.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eProfessional ECG Analysis Support\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Philips DXL algorithm can provide automated measurements and interpretive statements to assist ECG review.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eEasy Patient \u0026amp; Report Management\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe touchscreen interface simplifies patient information entry, ECG acquisition and report review.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eFlexible ECG Reporting\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eMultiple print formats allow the ECG report layout to be adapted to different clinical requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eBetter Signal-Quality Awareness\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eLead-off and signal-quality indicators can help identify electrode connection issues before or during acquisition.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eDigital Data Workflow\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eCompatible configurations support digital export and network-based ECG workflows, helping facilities integrate ECG records into broader information systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eSuitable for High-Use Clinical Environments\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe TC20 is designed as a professional cardiograph for hospitals, cardiac departments, diagnostic centres and outpatient healthcare environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h1\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePhilips Healthcare\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePageWriter TC20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12-Channel ECG Machine \/ Cardiograph\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eECG Acquisition\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSimultaneous 12-lead acquisition\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eECG Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eECG Algorithm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePhilips DXL ECG Algorithm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDisplay\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eColor TFT LCD Touchscreen\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTouchscreen\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRecording Modes\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAuto, Manual, Rhythm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eECG Formats\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3×4, 3×4+1R, 3×4+3R, 6×2, 12×1 and other configured formats\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRhythm Leads\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 12 configurable leads\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eECG History\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 5-minute history of all 12 leads, according to product documentation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSampling\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e500 Hz full-fidelity report storage; acquisition specifications may vary by configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFrequency Response\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 0.05–150 Hz, depending on configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMeasurements\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard ECG interval, duration and axis measurements\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInterpretation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAutomated interpretive statements with DXL\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePrinter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBuilt-in high-resolution thermal printer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePaper\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e210 mm \/ A4-compatible ECG paper specification\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFilters\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC, high-pass, low-pass and configured ECG filters\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLead Detection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLead-off advisory\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnectivity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSB, LAN; optional wireless depending on configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eData Formats\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePDF, XML, DICOM ECG depending on configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 200 reports listed in the supplied product specifications\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBattery\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRechargeable Lithium-Ion\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBattery Backup\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 30 minutes, according to supplied specification\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBattery Charging\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 4 hours\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC 100–240 V, 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 60 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 8.6 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eColor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWhite \u0026amp; Black\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 Year Manufacturer Warranty\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1\u003e\u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch3\u003e\u003cspan\u003e1. What is the Philips PageWriter TC20?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Philips PageWriter TC20 is a professional 12-channel ECG machine designed for simultaneous 12-lead ECG acquisition, measurement, interpretation, printing and digital ECG workflow.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e2. Is the Philips TC20 a 12-channel ECG machine?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYes. The TC20 supports simultaneous acquisition of all 12 ECG leads.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e3. Does the Philips PageWriter TC20 have a touchscreen?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYes. The supplied specifications list a color TFT LCD touchscreen.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e4. What ECG algorithm does the Philips TC20 use?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe TC20 uses the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ePhilips DXL ECG Algorithm\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for automated ECG measurements and interpretive support.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e5. Does the TC20 have a built-in printer?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYes. It includes an integrated high-resolution thermal printer.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e6. Can the Philips TC20 store ECG reports?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYes. The supplied product specifications list storage for up to 200 reports. Exact storage can vary according to configuration, so the supplied model should be verified before purchase.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e7. Does the TC20 support DICOM?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Philips product documentation indicates support for DICOM 12-lead ECG and DICOM General ECG in configured systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e8. Can the Philips TC20 connect to a hospital network?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYes, network connectivity is supported, with LAN and optional wireless functionality depending on the configuration. Philips documentation also describes network-based workflows such as worklists, ADT and ECG retrieval when connected to compatible systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e9. What is the warranty of the Philips PageWriter TC20?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe supplied product listing specifies a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1-year manufacturer warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e10. Is the Philips TC20 suitable for hospitals?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eYes. Its 12-lead acquisition, touchscreen interface, automated ECG analysis, integrated printer and optional digital connectivity make it suitable for professional hospital and diagnostic workflows.\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/medin.co.in%20%E2%80%BA%20collections%20%E2%80%BA%20collections-ecg-machines-dopplers\"\u003e\u003cstrong\u003eEXPLORE MORE EGC MACHINES ON MEDIN\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"MEDIN","offers":[{"title":"Default Title","offer_id":48212638892197,"sku":null,"price":190150.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/8786\/4997\/files\/Philips_PageWriter_TC20_12_Channel_ECG_Machine_with_Touchscreen.jpg?v=1788346778","url":"https:\/\/medin.co.in\/products\/philips-pagewriter-tc20-12-channel-ecg-machine","provider":"MEDIN","version":"1.0","type":"link"}