{"product_id":"contec-300ga-3-channel-ecg-machine","title":"Contec 300GA 3 Channel ECG Machine with 12-Lead ECG \u0026 Thermal Printer","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eContec 300GA 3 Channel ECG Machine\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is a compact digital electrocardiograph designed for routine ECG recording in hospitals, clinics, diagnostic centres and other healthcare settings. It supports simultaneous acquisition of \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e12-lead ECG signals\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e while recording selected ECG waveforms through its integrated thermal printing system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eDesigned for practical day-to-day ECG workflows, the machine supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eautomatic and manual recording modes\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, ECG waveform display, adjustable sensitivity and paper-speed settings, and patient case data management. Its digital signal processing incorporates power-frequency, baseline and EMG filtering to help produce clear ECG waveforms for clinical review.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe compact design, AC\/DC power operation and built-in rechargeable battery make the Contec 300GA suitable for healthcare facilities that need a portable ECG recording solution without occupying significant workspace. The machine measures approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e315 × 215 × 77 mm\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and weighs around \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1.6 kg\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, according to available product specifications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003eWhy Choose This Product?\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Contec 300GA is a practical choice for facilities looking for a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3-channel ECG machine with 12-lead acquisition and built-in thermal printing\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eKey reasons to consider this model:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e3-channel ECG recording with simultaneous 12-lead acquisition\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAutomatic and manual ECG recording modes\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBuilt-in thermal printer for ECG reports\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTFT LCD display for viewing ECG waveforms and operating information\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePatient case\/data storage capability\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAdjustable ECG sensitivity and paper speed\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDigital filtering for ECG signal processing\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAC power as well as rechargeable battery operation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCompact and portable design\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSuitable for routine ECG workflows in hospitals and clinics\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch3\u003e\u003cspan\u003e3-Channel ECG Recording\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Contec 300GA is designed for 3-channel ECG recording while supporting simultaneous acquisition of standard 12-lead ECG signals.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e12-Lead ECG Acquisition\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe device collects ECG signals from all standard 12 leads, supporting routine diagnostic ECG recording.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eAutomatic \u0026amp; Manual Modes\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe machine supports both automatic and manual ECG recording, allowing healthcare professionals to select the appropriate workflow.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eBuilt-In Thermal Printer\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAn integrated thermal printing system provides physical ECG reports using compatible \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e80 mm thermal paper\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eTFT LCD Display\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe 300GA\/300G platform is specified with a TFT LCD display for viewing ECG waveforms and operating information. Exact display colour should be verified against the supplied unit before publishing.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eECG Filtering\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe system incorporates power-frequency, baseline and EMG filtering to help process ECG signals and reduce common sources of interference.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003ePatient Data Management\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe ECG system supports case database management, allowing stored ECG cases to be reviewed as part of the device workflow.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eRechargeable Battery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe device supports AC power and rechargeable battery operation, providing flexibility for use in different clinical environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003eBenefits\u003c\/span\u003e\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eHelps streamline routine ECG recording\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSupports standard 12-lead ECG acquisition\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eConvenient printed ECG reports through the built-in thermal printer\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUseful for both automatic and manual recording workflows\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCompact size helps save clinical workspace\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBattery operation improves portability\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAdjustable recording parameters provide greater workflow flexibility\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePatient case storage can help with record review and management\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSuitable for hospitals, clinics and diagnostic facilities\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h1\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eContec\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Name\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eContec 300GA 3 Channel ECG Machine\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e300G \/ 300GA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eECG Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3 Channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eECG Leads\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 Lead\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLead Acquisition\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSimultaneous 12-lead acquisition\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRecording Mode\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAutomatic \/ Manual\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRecording System\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBuilt-in thermal printer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eThermal Paper\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e80 mm width\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDisplay\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTFT LCD\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTouchscreen\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Impedance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≥50 MΩ\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSensitivity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.5 \/ 5 \/ 10 \/ 20 \/ 40 mm\/mV depending on configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStandard Sensitivity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 mm\/mV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSampling Frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1000 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSampling Accuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12-bit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFrequency Response\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.05 Hz–150 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCMRR\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026gt;60 dB; \u0026gt;100 dB with filter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEMG Filter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25 \/ 35 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Frequency Filter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePatient Leakage Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt;10 µA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCalibration Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 mV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRecording Paper\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e80 mm × 20 m thermal paper\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePaper Speed\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 \/ 6.25 \/ 10 \/ 12.5 \/ 25 \/ 50 mm\/s depending on mode\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 1000 ECG cases\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAC Power\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100–240 V AC, 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBattery\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRechargeable lithium battery, 7.4 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBattery Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3500 mAh*\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBattery Backup\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 1.5 hours with continuous printing*\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e315 × 215 × 77 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNet Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 1.6 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSafety Classification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eClass I, Type CF, defibrillation protection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperation Mode\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eContinuous operation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 Year from manufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1\u003e\u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch3\u003e\u003cspan\u003e1. What is the Contec 300GA ECG machine?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Contec 300GA is a 3-channel digital ECG machine designed to acquire standard 12-lead ECG signals and record ECG waveforms through an integrated thermal printing system.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e2. How many leads does the Contec 300GA support?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe machine supports simultaneous acquisition of standard \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e12-lead ECG signals\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e3. Is the Contec 300GA a 3-channel ECG machine?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYes. It is designed as a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3-channel ECG machine\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with 12-lead ECG acquisition.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e4. Does the Contec 300GA have a built-in printer?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYes. The device uses a built-in thermal printing system for ECG reports and supports compatible 80 mm recording paper.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e5. Does the Contec 300GA work on battery?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYes. The system supports AC power and a rechargeable lithium battery, making it more convenient for portable clinical use.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e6. Does it support automatic ECG recording?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYes. The ECG300G platform supports automatic and manual recording modes. It can also automatically measure ECG waveform parameters.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e7. What size ECG paper does this machine use?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe machine uses \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e80 mm wide thermal ECG recording paper\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. The commonly specified paper size is 80 mm × 20 m.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e8. How much ECG data can the machine store?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAvailable specifications indicate storage of up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1000 ECG cases\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for the 300GA configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e9. What is the weight of the Contec 300GA?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe listed net weight is approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1.6 kg\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with dimensions of approximately 315 × 215 × 77 mm.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e10. Is the Contec 300GA suitable for hospitals and clinics?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eYes. Its 3-channel recording, 12-lead acquisition, thermal printing, automatic\/manual modes and portable form factor make it suitable for routine ECG workflows in hospitals, clinics and diagnostic facilities.\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/medin.co.in%20%E2%80%BA%20collections%20%E2%80%BA%20ecg-machines\"\u003e\u003cstrong\u003eEXPLORE MORE EGC MACHINES ON MEDIN\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"MEDIN","offers":[{"title":"Default Title","offer_id":48211171704997,"sku":null,"price":23529.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/8786\/4997\/files\/Contec_300GA_3_Channel_ECG_Machine_with_TFT_LCD_Display_and_Thermal_Printer.jpg?v=1788330178","url":"https:\/\/medin.co.in\/products\/contec-300ga-3-channel-ecg-machine","provider":"MEDIN","version":"1.0","type":"link"}